{"id":1534,"date":"2015-10-18T17:25:03","date_gmt":"2015-10-18T15:25:03","guid":{"rendered":"https:\/\/staging.esa-automation.com\/en\/?page_id=1534"},"modified":"2025-01-30T10:22:12","modified_gmt":"2025-01-30T09:22:12","slug":"ew800","status":"publish","type":"page","link":"https:\/\/staging.esa-automation.com\/it\/prodotti\/energy-management\/ew800\/","title":{"rendered":"EW800 SMART METER"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_section full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1710233875963{background-color: #000000 !important;}&#8221;][vc_row][vc_column css=&#8221;.vc_custom_1728921388138{padding-right: 0px !important;padding-left: 0px !important;}&#8221;][vc_single_image image=&#8221;17594&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; css_animation=&#8221;fadeIn&#8221;][\/vc_column][\/vc_row][\/vc_section][vc_row full_width=&#8221;stretch_row&#8221; equal_height=&#8221;yes&#8221; content_placement=&#8221;middle&#8221; css=&#8221;.vc_custom_1707228003784{background-color: #000000 !important;}&#8221;][vc_column width=&#8221;1\/2&#8243; css=&#8221;.vc_custom_1707228026491{padding-top: 0px !important;padding-right: 0px !important;padding-bottom: 0px !important;padding-left: 0px !important;}&#8221;][vc_column_text]<\/p>\n<h1><span style=\"color: #ffffff;\">EW800<\/span><\/h1>\n<h3><span style=\"color: #ffffff;\">Meter distribuito multifunzione<\/span><\/h3>\n<p><span style=\"color: #ffffff;\">Il meter distribuito per la misura puntuale dei consumi energetici di apparati e macchinari. In ottica IoT, invia autonomamente le informazioni raccolte al Data Manager per l\u2019analisi. In questo modo, promuove l\u2019efficienza energetica e la digitalizzazione nell\u2019impianto.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243; el_class=&#8221;puntato-bianco&#8221;][vc_gallery interval=&#8221;3&#8243; images=&#8221;12401,12402,12403&#8243; img_size=&#8221;full&#8221; onclick=&#8221;&#8221;][\/vc_column][\/vc_row][vc_section full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1707236036063{background-color: #00bab3 !important;}&#8221;][vc_row][vc_column css=&#8221;.vc_custom_1707239661132{margin-bottom: 0px !important;}&#8221;][vc_column_text css=&#8221;.vc_custom_1707240059708{margin-bottom: 0px !important;}&#8221;]<\/span><\/p>\n<h1><span style=\"color: #ffffff;\">Features<\/span><\/h1>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; equal_height=&#8221;yes&#8221; css=&#8221;.vc_custom_1707231915168{background-color: #00bab3 !important;}&#8221;][vc_column width=&#8221;1\/2&#8243; el_class=&#8221;puntato-bianco&#8221; css=&#8221;.vc_custom_1707239671058{padding-top: 0px !important;}&#8221;][vc_column_text]<\/p>\n<ul>\n<li>Display grafico 256\u00d796 pixel retroilluminato a LED bianchi.<\/li>\n<li>Menu intuitivo con interfaccia touch screen resistivo.<\/li>\n<li>Invio dati al Data Manager tramite ModBus RS485 o via Radio Sub1Ghz (868MHz).<\/li>\n<li>Possibilit\u00e0 di connettere a un singolo Data Manager EW900 fino a 250 meter.<\/li>\n<li>Contatore di energia trifase o monofase.<\/li>\n<li>Misura dell\u2019energia attiva, reattiva e apparente.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243; el_class=&#8221;puntato-bianco&#8221; css=&#8221;.vc_custom_1707240047809{padding-top: 0px !important;}&#8221;][vc_column_text]<\/p>\n<ul>\n<li>Misura della potenza attiva, reattiva e apparente.<\/li>\n<li>Misura dei parametri elettrici: corrente, tensione, potenza attiva, reattiva , apparente, fattore di potenza.<\/li>\n<li>Misura qualit\u00e0 della rete: armoniche (1st\u202651th), THD.<\/li>\n<li>Precisione: Class 1 per energia attiva.<\/li>\n<li>Aggiornamento dati: 1 secondo.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][\/vc_section][vc_row][vc_column][vc_row_inner][vc_column_inner][vc_empty_space][\/vc_column_inner][\/vc_row_inner][vc_accordion active_tab=&#8221;false&#8221; collapsible=&#8221;yes&#8221; el_class=&#8221;.accordionSmartMeter&#8221;][vc_accordion_tab title=&#8221;EW800A&#8221; el_id=&#8221;EW800A&#8221;][vc_column_text el_class=&#8221;productTextBoxContainer&#8221;]DEM (Distributed Embedded Meter) con shunt interni per per collegamento di punti di misura fino a 64A -, dotato di display LCD touch integrato display disponibile con<\/p>\n<ul>\n<li>Modulo I\/O integrato con 2 ingressi e 2 uscite digitali<\/li>\n<li>Interfaccia di comunicazione seriale RS485<\/li>\n<li>Interfaccia di comunicazione radio RF868 MHZ<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_column_text el_class=&#8221;tableDownloadPDF&#8221;]<a href=\"https:\/\/staging.esa-automation.com\/wp-content\/uploads\/2018\/03\/EW800.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Scarica pdf<\/a><\/p>\n<p>\n<table id=\"tablepress-24\" class=\"tablepress tablepress-id-24\">\n<thead>\n<tr class=\"row-1\">\n\t<td class=\"column-1\"><\/td><th class=\"column-2\">EW800A DEM<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Connections<\/td><td class=\"column-2\">Single-phase<br \/>\nThree-phase 4 wires with Y load<br \/>\nThree-phase 4 wires with D load<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Measuring inputs - Current Channels<\/td><td class=\"column-2\">Direct<br \/>\nup to 64A (45kW) three-phase connection,<br \/>\nup to 21A (15kW) single-phase connection<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Measuring inputs - Voltage Channels<\/td><td class=\"column-2\">Direct<br \/>\n(max rated voltage phase-neutral 230Vac)<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Power supply<\/td><td class=\"column-2\">self-powered<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Communication<\/td><td class=\"column-2\">RS485 ModBus (in all EW800\u2026 models)<br \/>\nRadio RF868 MHz (only in EW800\u2026200 models)<br \/>\nEthernet (only in EW800\u2026300 models)<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Digital Isolated Input\/Output<\/td><td class=\"column-2\">2 I\/O module option (configurable by Data Manager)<br \/>\nTHD<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Measures<\/td><td class=\"column-2\">Voltage (phase-neutral and phase-phase)<br \/>\nCurrent (phase values and neutral value)<br \/>\nImported Active Energy (phase values and total value)<br \/>\nExported Active Energy (phase values and total value)<br \/>\nImported Active Power (phase values and total value)<br \/>\nExported Active Power (phase values and total value)<br \/>\nReactive Power with sign (phase values and total value)<br \/>\nApparent Power (phase values and total value)<br \/>\nPower Factor (phase values and total value)<br \/>\nFrequency<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Harmonic analysis<\/td><td class=\"column-2\">THD (in voltage \/ current signal) Harmonics 1st ...51st (in voltage \/ current signal)<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Accuracy - Active Energy<br \/>\n(according to IED 62053-21)<\/td><td class=\"column-2\">Class 1<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Accuracy - Reactive Energy<br \/>\n(according to IED 62053-23)<\/td><td class=\"column-2\">Class 2<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Accuracy - Current and Voltage<\/td><td class=\"column-2\">\u2264 0,5%<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Display<\/td><td class=\"column-2\">LCD (256 x 96 pixel) and resistive touch screen<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Case - Mounting<\/td><td class=\"column-2\">DIN rail<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Case - No. DIN modules<\/td><td class=\"column-2\">7<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">Case - External dimensions<br \/>\n(mm)<\/td><td class=\"column-2\">126 x 100 x 70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-24 from cache -->[\/vc_column_text][\/vc_accordion_tab][vc_accordion_tab title=&#8221;EW800B&#8221; el_id=&#8221;EW800B&#8221;][vc_column_text el_class=&#8221;productTextBoxContainer&#8221;]DTM (Distributed External TA Meter) per rilevazione attraverso TA esterni, dotato di display LCD touch integrato display disponibile con<\/p>\n<ul>\n<li>Modulo I\/O integrato con 2 ingressi e 2 uscite digitali<\/li>\n<li>Interfaccia di comunicazione seriale RS485<\/li>\n<li>Interfaccia di comunicazione radio RF868 MHZ<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_column_text el_class=&#8221;tableDownloadPDF&#8221;]<a href=\"https:\/\/staging.esa-automation.com\/wp-content\/uploads\/2018\/03\/EW800.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Scarica pdf<\/a><\/p>\n<p>\n<table id=\"tablepress-25\" class=\"tablepress tablepress-id-25\">\n<thead>\n<tr class=\"row-1\">\n\t<td class=\"column-1\"><\/td><th class=\"column-2\">EW800B DTM<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Connections<\/td><td class=\"column-2\">Single-phase<br \/>\nTwo-phase<br \/>\nThree-phase with neutral<br \/>\nThree-phase without neutral<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Measuring inputs - Current Channels<\/td><td class=\"column-2\">with external Current<br \/>\nTransformers<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Measuring inputs - Voltage Channels<\/td><td class=\"column-2\">Direct<br \/>\n(max rated voltage phase-neutral 230Vac) or<br \/>\nwith external Voltage Transformer<br \/>\n(rated secondary voltage 100-115Vac, for LV or MV application)<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Power supply<\/td><td class=\"column-2\">100\u00f7230Vac<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Communication<\/td><td class=\"column-2\">RS485 ModBus (in all EW800\u2026 models)<br \/>\nRadio RF868 MHz (only in EW800\u2026200 models)<br \/>\nEthernet (only in EW800\u2026300 models)<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Digital Isolated Input\/Output<\/td><td class=\"column-2\">Voltage (phase-neutral and phase-phase)<br \/>\nCurrent (phase values and neutral value)<br \/>\nImported Active Energy (phase values and total value)<br \/>\nExported Active Energy (phase values and total value)<br \/>\nImported Active Power (phase values and total value)<br \/>\nExported Active Power (phase values and total value)<br \/>\nReactive Power with sign (phase values and total value)<br \/>\nApparent Power (phase values and total value)<br \/>\nPower Factor (phase values and total value)<br \/>\nFrequency<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Harmonic analysis<\/td><td class=\"column-2\">THD (in voltage \/ current signal) Harmonics 1st ...51st (in voltage \/ current signal)<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Accuracy - Active Energy<br \/>\n(according to IED 62053-21)<\/td><td class=\"column-2\">Class 1<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Accuracy - Reactive Energy<br \/>\n(according to IED 62053-23)<\/td><td class=\"column-2\">Class 2<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Accuracy - Current and Voltage<\/td><td class=\"column-2\">\u2264 0,5%<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Display<\/td><td class=\"column-2\">LCD (256 x 96 pixel) and resistive touch screen<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Case - Mounting<\/td><td class=\"column-2\">DIN rail<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Case - No. DIN modules<\/td><td class=\"column-2\">5<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Case - External dimensions<br \/>\n(mm)<\/td><td class=\"column-2\">90 x 96 x 70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-25 from cache -->[\/vc_column_text][\/vc_accordion_tab][vc_accordion_tab title=&#8221;EW800C&#8221; el_id=&#8221;EW800C&#8221;][vc_column_text el_class=&#8221;productTextBoxContainer&#8221;]DRM (Distributed External Rogowski Meter) per rilevazione attraverso Rogowski coils esterni, dotato di display LCD touch integrato display disponibile con<\/p>\n<ul>\n<li>Modulo I\/O integrato con 2 ingressi e 2 uscite digitali<\/li>\n<li>Interfaccia di comunicazione seriale RS485<\/li>\n<li>Interfaccia di comunicazione radio RF868 MHZ<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_column_text el_class=&#8221;tableDownloadPDF&#8221;]<a href=\"https:\/\/staging.esa-automation.com\/wp-content\/uploads\/2018\/03\/EW800.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Scarica pdf<\/a><\/p>\n<p>\n<table id=\"tablepress-26\" class=\"tablepress tablepress-id-26\">\n<thead>\n<tr class=\"row-1\">\n\t<td class=\"column-1\"><\/td><th class=\"column-2\">EW800C DRM<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Connections<\/td><td class=\"column-2\">Single-phase<br \/>\nTwo-phase<br \/>\nThree-phase with neutral<br \/>\nThree-phase without neutral<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Measuring inputs - Current Channels<\/td><td class=\"column-2\">with external Rogowski coils<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Measuring inputs - Voltage Channels<\/td><td class=\"column-2\">Direct<br \/>\n(max rated voltage phase-neutral 230Vac) or<br \/>\nwith external Voltage Transformer<br \/>\n(rated secondary voltage 100-115Vac, for LV or MV application)<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Power supply<\/td><td class=\"column-2\">100\u00f7230Vac<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Communication<\/td><td class=\"column-2\">RS485 ModBus (in all EW800\u2026 models)<br \/>\nRadio RF868 MHz (only in EW800\u2026200 models)<br \/>\nEthernet (only in EW800\u2026300 models)<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Digital Isolated Input\/Output<\/td><td class=\"column-2\">2 I\/O module option (configurable by Data Manager)<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Measures<\/td><td class=\"column-2\">Voltage (phase-neutral and phase-phase)<br \/>\nCurrent (phase values and neutral value)<br \/>\nImported Active Energy (phase values and total value)<br \/>\nExported Active Energy (phase values and total value)<br \/>\nImported Active Power (phase values and total value)<br \/>\nExported Active Power (phase values and total value)<br \/>\nReactive Power with sign (phase values and total value)<br \/>\nApparent Power (phase values and total value)<br \/>\nPower Factor (phase values and total value)<br \/>\nFrequency<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Harmonic analysis<\/td><td class=\"column-2\">THD (in voltage \/ current signal) Harmonics 1st ...51st (in voltage \/ current signal)<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Accuracy - Active Energy<br \/>\n(according to IED 62053-21)<\/td><td class=\"column-2\">Class 1<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Accuracy - Reactive Energy<br \/>\n(according to IED 62053-23)<\/td><td class=\"column-2\">Class 2<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Accuracy - Current and Voltage<\/td><td class=\"column-2\">\u2264 0,5%<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Display<\/td><td class=\"column-2\">LCD (256 x 96 pixel) and resistive touch screen<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Casec -Mounting<\/td><td class=\"column-2\">DIN rail<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Case - No. DIN modules<\/td><td class=\"column-2\">5<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">Case - External dimensions<br \/>\n(mm)<\/td><td class=\"column-2\">90 x 96 x 70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-26 from cache -->[\/vc_column_text][\/vc_accordion_tab][vc_accordion_tab title=&#8221;CODICI DI ORDINAZIONE&#8221;][vc_column_text el_class=&#8221;productTextBoxContainer&#8221;]\n<table id=\"tablepress-125\" class=\"tablepress tablepress-id-125\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">CODES<\/th><th class=\"column-2\">DESCRIPTION<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">EW800A<\/td><td class=\"column-2\"><\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">EW800A3A100<\/td><td class=\"column-2\">DEM (Distributed Embedded Meter) with internal shunts for current measurements up to 64A - integrated  touch LCD display - serial communication interface RS485<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">EW800A3A122<\/td><td class=\"column-2\">DEM (Distributed Embedded Meter) with internal shunts for current measurements up to 64A - integrated I\/O module with 2 digital inputs and 2 digital outputs - integrated  touch LCD display - serial communication interface RS485<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">EW800A3A200<\/td><td class=\"column-2\">DEM (Distributed Embedded Meter) with internal shunts for current measurements up to 64A - integrated  touch LCD display - radio communication interface RF868 MHZ<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">EW800A3A222<\/td><td class=\"column-2\">DEM (Distributed Embedded Meter) with internal shunts for current measurements up to 64A - integrated I\/O module with 2 digital inputs and 2 digital outputs - integrated  touch LCD display - radio communication interface RF868 MHZ<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">EW800B<\/td><td class=\"column-2\"><\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">EW800B3A100<\/td><td class=\"column-2\">DTM (Network External TA Meter) with external TA for current measurements - integrated  touch LCD display - serial communication interface RS485<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">EW800B3A122<\/td><td class=\"column-2\">DTM (Distributed External TA Meter) with external TA for current measurements  - integrated I\/O module with 2 digital inputs and 2 digital outputs - integrated  touch LCD display - serial communication interface RS485<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">EW800B3A200<\/td><td class=\"column-2\">DTM (Distributed External TA Meter) with external TA for current measurements  - integrated  touch LCD display - radio communication interface RF868 MHZ<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">EW800B3A222<\/td><td class=\"column-2\">DTM (Distributed External TA Meter) with external TA for current measurements  - integrated I\/O module with 2 digital inputs and 2 digital outputs - integrated  touch LCD display - radio communication interface RF868 MHZ<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">EW800B3A300<\/td><td class=\"column-2\">DTM (Distributed External TA Meter) with external TA for current measurements  - integrated  touch LCD display - Modbus TCP\/IP LAN interface<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">EW800B3A322<\/td><td class=\"column-2\">DTM (Distributed External TA Meter) with external TA for current measurements  - integrated I\/O module with 2 digital inputs and 2 digital outputs - integrated  touch LCD display - Modbus TCP\/IP LAN interface<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">EW800C<\/td><td class=\"column-2\"><\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">EW800C3A100<\/td><td class=\"column-2\">DRM (Distributed External Rogowski Meter) with external Rogowski coils for current measurements - integrated  touch LCD display - serial communication interface RS485<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">EW800C3A122<\/td><td class=\"column-2\">DRM (Distributed External Rogowski Meter) with external Rogowski coils for current measurements  - integrated I\/O module with 2 digital inputs and 2 digital outputs - integrated  touch LCD display - serial communication interface RS485<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">EW800C3A200<\/td><td class=\"column-2\">DRM (Distributed External Rogowski Meter) with external Rogowski coils for current measurements - integrated  touch LCD display - radio communication interface RF868 MHZ<\/td>\n<\/tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">EW800C3A222<\/td><td class=\"column-2\">DRM (Distributed External Rogowski Meter) with external Rogowski coils for current measurements  - integrated I\/O module with 2 digital inputs and 2 digital outputs - integrated  touch LCD display - radio communication interface RF868 MHZ<\/td>\n<\/tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">EW800C3A300<\/td><td class=\"column-2\">DRM (Distributed External Rogowski Meter) with external Rogowski coils for current measurements  - integrated  touch LCD display - Modbus TCP\/IP LAN interface<\/td>\n<\/tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">EW800C3A322<\/td><td class=\"column-2\">DRM (Distributed External Rogowski Meter) with external Rogowski coils for current measurements  - integrated I\/O module with 2 digital inputs and 2 digital outputs - integrated  touch LCD display - Modbus TCP\/IP LAN interface<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-125 from cache --><\/p>\n<p>[\/vc_column_text][\/vc_accordion_tab][\/vc_accordion][vc_empty_space height=&#8221;40px&#8221;][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Meter distribuito multifunzione<\/p>\n","protected":false},"author":4,"featured_media":17599,"parent":989,"menu_order":7,"comment_status":"open","ping_status":"closed","template":"tmpprodotti.php","meta":{"_acf_changed":false,"footnotes":""},"tags":[33,110,21],"class_list":["post-1534","page","type-page","status-publish","has-post-thumbnail","hentry","tag-ew800","tag-ew800-prodotti","tag-prodotti"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/staging.esa-automation.com\/it\/wp-json\/wp\/v2\/pages\/1534","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/staging.esa-automation.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/staging.esa-automation.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/staging.esa-automation.com\/it\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/staging.esa-automation.com\/it\/wp-json\/wp\/v2\/comments?post=1534"}],"version-history":[{"count":0,"href":"https:\/\/staging.esa-automation.com\/it\/wp-json\/wp\/v2\/pages\/1534\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/staging.esa-automation.com\/it\/wp-json\/wp\/v2\/pages\/989"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/staging.esa-automation.com\/it\/wp-json\/wp\/v2\/media\/17599"}],"wp:attachment":[{"href":"https:\/\/staging.esa-automation.com\/it\/wp-json\/wp\/v2\/media?parent=1534"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/staging.esa-automation.com\/it\/wp-json\/wp\/v2\/tags?post=1534"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}